- IO Modules
- Protocol Converter
- PLC
- Industrial Switch
0102030405
BN-8021 CANopen COMM Board IO Card
Technical Parameters
Notice: This BN-8032-L Profinet COMM board doesn't support the MRPD (Media Redundancy for Planned Duplication) function, so the MRP and IRT functions cannot be used simultaneously.
| COMM Board Hardware Parameter | |
| System Power |
Power:19.2~28.8VDC(Nominal:24VDC)
Protection:Reverse Protection
|
| Power Consumption | 100mA@24Vdc |
| IO module supported | Max:4pcs(B32 support 2pcs,B64 support 4pcs) |
| Wiring diameter | Max.1.5mm²(AWG 16) |
| Environment Parameter | |
| Operation Temperature | -30~75℃ |
| Operation Humidity | 5%-95%(No Condensation) |
| IP Grade | IP20 |
| Profinet Parameter | |
| Network Protocol | Profinet IO Device |
| Process Data Area | Input Max 1440 Bytes,Output Max 1440 Bytes |
| RT | Supported,Min.period is 1ms |
| IRT | Not supported |
| MRP | Not supported |
| MRPD | Not supported |
| Network Interface | 2*RJ45 |
| Speed | 10/100MbpsMDI/MIDX,Full-Duplex |
| Profinet Device Name | Profinet Monitor Modifies the device name |