- IO Modules
- Protocol Converter
- PLC
- Industrial Switch
C3351-B01 Modbus-TCP Modbus RTU PLC controller codesysv3.5 Programmable Micro PLC-1
-
Expansion32 Modules
-
Programming LanguageIEC 61131-3 (LD, IL, ST, CFC/FBD, SFC)
-
Program Memory4MBytes
-
Data Storage4MBytes
PRODUCT DESCRIPTION
CODESYS Software Download Link: https://store.codesys.com/en/codesys.html
With built-in Ethernet (Modbus TCP) and Serial (Modbus RTU) interfaces, the C3351-B01 serves as a versatile controller for small-to-medium automation systems, seamlessly connecting IT and OT environments.
Key Technical Features
-
Flexible expansion: support
The supported I/O expansion modules include:
A.Digital Input Module
B.Digital Output Module
C.Analog Input Module
D.Analog Output Module
E.Special Function Module -
Global Standard Programming
owered by the robust CODESYS V3.5 engine, the C3351-B01 supports all 5 standard IEC 61131-3 languages (LD, ST, FBD, IL, SFC), ensuring code portability and a familiar development environment for engineers worldwide.
-
Versatile Communication Capabilities
The CPU's Ethernet port supports Modbus TCP (Client/Server) for third-party data exchange. Its RS485 port supports Modbus RTU (Master/Slave) for serial communication. These versatile interfaces allow the PLC to integrate seamlessly with diverse third-party devices in various automation systems.
Technical Specifications
|
Module Name |
C3351-A00 |
C3351-B01 |
|
Programming Software |
||
|
Programming Language |
IEC 61131-3 (LD, IL, ST, CFC/FBD, SFC) |
|
|
Maximum State Task |
5 |
|
|
Program Memory |
1M Bytes |
4M Bytes |
|
Data Storage |
1M Bytes |
4M Bytes |
|
Power-down Protection |
1.5K Bytes |
32K Bytes |
|
Bit Instruction Cycle |
0.0738us |
|
|
Word Transfer Cycle |
0.33us |
|
|
Float Operation Cycle |
0.38us |
|
|
RTC |
Not Supported |
|
|
Maximum Expansion |
32 |
|
|
Modbus Master Max |
10 |
|
|
Modbus Master |
Function Code 1(Read Coils): 2000/per channel |
|
|
General Parameters |
||
|
System Power |
19.2~28.8VDC (Nominal: 24VDC) |
|
|
System supply current |
Max. DC 2A |
|
|
Module Consumption |
110mA@24VDC |
|
|
Internal Bus Supply |
Max:2.0A@5VDC |
|
|
Field Power |
19.2~28.8VDC (Nominal: 24VDC) |
|
|
Field Power Current |
Max. DC 8A |
|
|
Wirring Diameter |
Max.1.5mm² (AWG 16) |
|
|
Installation |
35mm DIN rail |
|
|
Dimension |
115 * 65.5 * 75mm |
|
|
Weight |
170g |
|
|
Interface Parameters |
||
|
Interface |
2 * RJ45,1 * RS485 |
|
|
Network Protocol |
Modbus TCP ,Modbus RTU |
|
|
RS485 Parameter |
Support Modbus RTU/ASCII |
|
|
Ethernet Parameter |
10/100Mbps, Adaptive and full duplex |
|
|
Modbus TCP Client |
Max supports for connecting 6 Modbus TCP servers |
|
|
Modbus TCP Server |
Max supports for 6 Modbus TCP clients connected |
|
|
Modbus RTU Master |
Max supports for connecting 5 slave devices |
|
|
Modbus RTU Slave |
Max supports for connecting 1 master device |
|
|
Environmental Parameters |
||
|
Operating Temperature |
-35℃-70℃ |
|
|
Operating Temperature |
-35℃-60℃ |
|
|
Relative Humidity |
5-95%RH (No Condensation) |
|
|
Storage Temperature |
-40℃-85℃ |
|
|
Storage Humidity |
5-95%RH (No Condensation) |
|
|
Manufacturing Test |
-40℃-75℃ |
|
|
Ingress Protection |
IP20 |
|
|
Anti-pollution Rating of |
Pollution level 2 |
|
|
Altitude |
< 2000 m |
|
A:Compliant with IEC61131-3, it supports LD, IL, ST, FBD/CFC, and SFC, suitable for a wide range of industrial automation applications.
A:Up to 32 C-series remote IO modules, enabling distributed control system applications.
A:Dual Ethernet interfaces, supporting Modbus-TCP Server/Client and Modbus-RTU Master/Slave, allowing seamless integration with SCADA and other devices.
Ideal for industries requiring high-speed, cost-effective distributed I/O:


Automotive Industry