China Factory for Modbus-Rtu Converter - MG-CANEX CANopen to Modbus TCP converter – ODOT factory and manufacturers | ODOT

China Factory for Modbus-Rtu Converter - MG-CANEX CANopen to Modbus TCP converter – ODOT

Product Feature:


Product Detail

Product Tags

Product Download

Related Video

Feedback (2)

abide by the contract", conforms to the market requirement, joins during the market competition by its superior quality also as provides extra comprehensive and exceptional service for consumers to let them turn into significant winner. The pursue of the business, is definitely the clients' gratification for beckhoff ethercat io module , 8 Poe , Moxa Din Rail Switch , We have now a experienced crew for international trade. We are able to solve the problem you meet. We are able to offer the products and solutions you want. You should really feel free of charge to speak to us.
China Factory for Modbus-Rtu Converter - MG-CANEX CANopen to Modbus TCP converter – ODOT Detail:

Product Details

◆ The gateway comes with its own configuration software, and the parameter configuration information is downloaded to the gateway through the network port. The gateway automatically saves the latest configuration information. There is no need to load configuration after the gateway is powered off and on.◆ Gateway is the master of CANopen on CANopen network, and can connect to the equipment of CANopen slave ◆ The gateway is Modbus Server on Modbus TCP network and supports up to 5 TCP clients access. Double Ethernet port, with switch function, support cascade.◆ 2KV network port isolation protection, 10M/100Mbps rate adaptive, automatic MDI/MDIX reversal.◆ It supports address mapping mode, and realize the rapid response to TCP client request.◆ Modbus TCP supports function code: 0 x01, 0 x02, 0 x03, 0 x04, 0 x05, 0 x06, 0 x0F, 0 x10.◆ 6KB large data buffer, more data transfer volume.◆ CAN interface supports CANopen working mode.◆ CAN interface Baud rate: 10K~1Mbps.◆ CANopen protocol conforms to DS301 V4.02 and supports NMT master, PDO, SDO and Heartbeat.◆ It supports one-key reset function to restore factory Settings.◆ 35mm DIN-rail installation.◆ EMC meets EN 55022:2010 & EN55024:2010 international standards.

Product Characteristic

MG-CANEX Protocol Converter

CANopen to Modbus TCP protocol converter

MG-CANEX is a protocol converter from CANopen to Modbus TCP. The device plays as the master in the CANopen network and it could be connected to the standard CANopen slave devices. The data transmission supports PDO, SDO, and error control supports Heartbeat. It Supports synchronous and asynchronous message sending.As a TCP server in Modbus TCP network, the device could be accessed by 5 TCP clients at the same time, and it could be connected to PLC controller and various kinds of configuration software. It could also connect optical transceiver and to realize long-distance data transmission.

Fusce ac img

Technical Parameters

Technical parametersPlease use this product within the parameters of this product to obtain better performance.

Environmental parametersWorking temperature: -40~85℃/-20~70℃ optionalStorage temperature : -45~125℃Working humidity: 5%~95% ( No condensation )The power supply parametersNumber of power ports: 1wayInput voltage range: 9~36VDC,3KV isolation voltagePower consumption: Max.110mA@24VEthernet parametersModbus TCP Function code: 0×01,0×02,0×03,0×04,0×05,0×06,0x0F,0x10Number of Ethernet ports: 2PCs of RJ45,10M,100M adaptive rate with switch functionNetwork protocol: ETHERNET,ARP,IP,TCP,ICMPNumber of TCP connections: The five largestModbus data store:0xxxx area( coil ):8192 Bit1xxxx area( Discrete input ):8192 Bit3xxxx area( Input register ):2048 Word4xxxx area( Hold register ):2048 Word

CANopen parametersCAN baud rate: 10K~1MbpsCAN protocol: CANopenNumber of slave supported: 16 stationsPDO functions: Support TPDO, RPDO data transmissionSDO functions: Fast SDO transfers of up to 4 bytes are supportedError control: Support the Heartbeat

Technical Parameters

Fusce ac img


Product detail pictures:

China Factory for Modbus-Rtu Converter - MG-CANEX CANopen to Modbus TCP converter – ODOT detail pictures


Related Product Guide:

We take "customer-friendly, quality-oriented, integrative, innovative" as objectives. "Truth and honesty" is our management ideal for China Factory for Modbus-Rtu Converter - MG-CANEX CANopen to Modbus TCP converter – ODOT , The product will supply to all over the world, such as: New Zealand, Chicago, Hungary, We have top engineers in these industries and an efficient team in the research. What is more, now we have our own archives mouths and markets in China at low cost. Therefore, we can meet different inquiries from different clients. Remember to find our website to check more information from our merchandise.
    • In general, we are satisfied with all aspects, cheap, high-quality, fast delivery and good procuct style, we will have follow-up cooperation!
      5 StarsBy Fernando from Malta - 2017.06.19 13:51
      Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
      5 StarsBy Deborah from Kazakhstan - 2018.09.29 13:24