Leave Your Message
Products Categories
Featured Products

DN-8032-L PROFINET Network Adapter Remote IO System

The DN8032-L network adapter supports standard PROFINET IO Device

protocol, and it supports dual network port switch cascade function;The module not supports the MRP media redundancy and the redundant ring network, it supports RT real-time communication mode, RT real-time communication minimum period is 1ms;

    • Min. Cycle Time
      0.6 ms
    • Expansion
      32 Modules
    • Wirring Diameter
      3.Min.0.2mm²(AWG24) Max.1.5mm²(AWG16)
    • Service
      ODM&OEM

    PRODUCT DESCRIPTION

    ODOT DN-8032-L PROFINET RT IRT Adapter
    PROFINET is an industrial Ethernet standard developed by the PNO (PROFIBUS Network Organization). PROFINET IO describes multiple real-time levels of data exchange between controllers and field devices: RT (software-based real-time communication) and IRT (hardware-based synchronous real-time communication).

    ODOT DN-8032-L PROFINET io system
    The ODOT DN-8032-L PROFINET Adapter is fully compatible with major Profinet Controllers, including Siemens S7-1200, S7-1500, S7-300, and S7-400. Setup is effortless using standard GSDML files in TIA Portal or Step7.

    Product Feature
    The ODOT DN-8032-L is a user-friendly Profinet network adapter designed for standard industrial automation applications. It connects up to 32 I/O modules to a Profinet network. Distinct from standard adapters, it features an integrated OLED screen for immediate parameter viewing without software, and removable spring-clamp terminals for fast wiring.

    Key Technical Features

    • 793a0eed-e7fd-4cec-aed4-8a7c7fe1935d

      Removeable terminals _ Easier Installation

      (1) Staggered spring-loaded guided terminals
      (2) Removeable terminals for easy module maintenance and replacement

    • abe40f07-4608-4e6f-a439-8cdac43443d5

      Redundant Backplane _ Enhanced Reliability

      (1) Backplane bus supports redundancy
      (2) Supports up to 32 I/O modules
      (3) Full load refresh cycle of 0.6 ms

    • 0841450c-88dd-4af9-ae75-61adb10a1291

      Superior EMC Performance

      EMC performance far exceeds IEC 61000-4 standard

    Technical Specifications

    General Parameter

    Current Consumption

    107mA@24VDC

    System Power

    19.2~28.8VDC (Nominal: 24VDC)

    Anti-inversion protection: support

    Internal Bus Supply Current

    Max.2A@5VDC

    Field Power

    19.2~28.8VDC (Nominal: 24VDC)

    Field Power Current

    Max. DC 8A

    Wirring Diameter

    Min.0.2mm²(AWG24)

    Max.1.5mm²(AWG16)

    Terminal Pluggable

    Support

    The Maximum Number of Expansion Modules

    32

    Diagnosis Function

    Communication diagnostics, extended module status diagnostics

    Backplane Bus

    Double bus redundancy

    Installation

    35mm DIN-Rail

    Dimension

    119*83*80mm

    Product Certification

    CE Certification

    Communication Parameters

    Protocol

    PROFINET IO Device

    Input

    1440 bytes

    Output

    1440 bytes

    Transmission Speed

    10/100 Mbps

    RT

    Support, RT real-time communication minimum period is 1ms

    IRT

    Not support

    MRP

    Not support

    MRPD

    Not support

    Device Name Setting

    DIP switch or software configuration

    Environment Parameters

    Horizontal Installation Operating Temperature

    -35℃~60℃

    Vertical Installation Operating Temperature

    -35℃~50℃

    Storage Temperature

    -40℃~85℃

    Environment Humidity

    5%~95%RH (No condensation)

    Installation Altitude

    <2000m

    Pollution Degree

    Protection Grade

    IP20

    Mechanical Properties

    Comply with IEC60068-2-6, IEC6008-2-27

    Insulation Withstand

    Comply with IEC61131-2

     

     

    EMC Performance

    Comply with IEC61131-2, IEC61000-4

    ESD: Contact discharge±6kV, Air discharge±8kV, Performance

    level A;

    SURGE: Common mode ±2kV, Differential mode±1kV,

    Performance level A;

    EFT: ±2kV, Performance level A)

    S FAQ

    PRODUCTS FAQ

    needs
    9623b2b9-15e5-4a0a-a03f-9a50f54e0200
    Q: What is the benefit of the built-in OLED screen?

    A:The OLED screen allows engineers to view critical parameters—such as the IP address, subnet mask, and module operating status—directly on the device without needing to connect a laptop or install software. This significantly speeds up on-site maintenance and troubleshooting.

    fca08b09-f435-4767-b405-388d9ef8ffbc
    Q:Can I replace the module or wiring without disconnecting the cables?

    A:Yes. The DN-8032-L utilizes pluggable spring terminals. This allows you to unplug the terminal block with the wires still attached, making module replacement or maintenance quick and easy without re-wiring.

    Why Choose ODOT?

    We understand the challenges the automation industry faces today. The DN-8032-L is more than just a hardware component; it's a solution designed to optimize your business efficiency.


    minimized1
    Fast & Reliable Delivery
    If you are facing: Global supply chain disruptions causing long lead times (6-12 months) for critical automation parts.

    Our Solution: We maintain a robust supply chain and ample stock levels. ODOT guarantees rapid delivery (Most products can be shipped within 1-3 working days,typically shipping within 1-2 weeks for standard orders), ensuring your project stays on schedule and machine downtime is minimized.
    24/7 Global Technical Support
    If you are facing: Lack of timely support during commissioning, leading to project delays.

    Our Solution: We provide 24-hour technical support. Our team of dedicated application engineers is available around the clock to assist with GSDML file configuration, PLC integration (Siemens S7-1200/1500, etc.), and troubleshooting, ensuring a smooth setup process regardless of your time zone.
    Certifications & Quality Assurance:
    ODOT products comply with international industrial standards, including CE,UL, RoHS, CL and CCS certifications, having undergone rigorous quality control to ensure long-term reliable operation in industrial environments.
    environments
    ODOT In Hannover Messe
    Germany
    Professional Team
    Team

    Leave Your Message

    New Products Recommendation