Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT factory and manufacturers | ODOT

Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT

Product Feature:


Product Detail

Product Tags

Product Download

Related Video

Feedback (2)

Reliable quality and good credit standing are our principles, which will help us at a top-ranking position. Adhering to the tenet of "quality first, customer supreme" for Ethernet Network Adapter Card , Industrial Iot Solutions , Remote Io Ethernet Ip , Your aid is our everlasting power! Warmly welcome clients in your own home and abroad to go to our enterprise.
Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT Detail:

Product Details

IntroductionODOT-S2E2/S4E2 gateway is a Modbus-RTU/ASCII to Modbus-TCP protocol converter. This product can connect Modbus device to PLC and master computer that supports Modbus-TCP (client) functions. It supports the connection of 5TCPclients simultaneously. And the product adopts aluminum alloy shell with firm design and supports DIN-rail installation. All serial signal provide built-in photoelectric isolation.

Product Characteristic

♦Supports protocol conversion between Modbus-RTU and Modbus-TCP♦Supports the connection of5 TCP clients simultaneously♦ODOT-S2E2 supports 2*RS485♦ODOT-S4E2 supports wiring of RS485/RS232/RS422♦Each serial port supports Modbus masterand slave♦ODOT-S2E2:2 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway♦ODOT-S4E2:4 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway♦Supports one key reset♦Gateway working mode: Transparent transmission, address mapping

Technical Parameters

Mechanical PropertyShell: Aluminum alloyWeight: 305g(ODOT-S2E2)NewDimension: 27.5*110*110mmWorking Temperature: -40 〜85°CStorage Temperature: -55 〜125°CRelative Humidity: 5 〜95%(no condensation)Input Voltage: 9〜36 VDCWiring: 3.81mm plug screw terminalPower: Max.l00mA@24V(ODOT-S2E2) Max.200mA@24V(ODOT-S4E2)

Modbus SerialPort Number: 2(ODOT-S2E2) 4(ODOT-S4E2)Port Protocol: Modbus-RTU/ASCIISerial Standard: 2*RS485(ODOT-S2E2) OR RS485/RS232/RS422(ODOT-S4E2)Wiring: 3.81mm plug screw terminalESD Protection: ±16KVRs485 Terminal Resistance: External 120ΩData Bits: 7,8Stop Bits: 1,2Check digit: None, even, oddBaud Rate: 1200~115200 bpsOn load: Each serial port theoretically can hang 31 pcs of devices (Rs485/RS422)

Ethernet InterfaceProtocol: Modbus-TCP serverPorts Number: 2 pcs (supports switching function)Communication Rate: l0M/l00Mbps, self-adaptiveConnector: RJ45

Main Technical ParametersNetwork Working Mode: Transparent transmission and address mapping are optional, Modbus TCP protocolNetwork Protocol: ETHERNET,ARP,IP,TCP,ICMPTCP Connection: Max. 5 pcsSupports Slave: Max. 62pcs (no relay)Mapping Mode Protocol Function Code: 0×01,0×02,0×03,0×04,0×05,0×06,0x0F, 0x10Modbus Data Storage Area:0xxxx area (coil): 8192 BitIxxxx area(discrete input): 8192 Bit3xxxx area (input register): 2048 Word4xxxx area (holding register): 2048 Word3xxxx area (system diagnosis area): 263 Word

Ordering InformationODOT-S2E2: 2 Ports Modbus RTU/ASCII to Modbus TCP Server Gateway, Serial supports RS485,9-36V DC, -40~85°CODOT-S4E2: 4 Ports Modbus RTU/ASCII to Modbus TCP Server Gateway, Serial supports RS485,9~36V DC, -40~85°C

 

Technical Parameters


Product detail pictures:

Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT detail pictures

Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT detail pictures

Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT detail pictures

Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT detail pictures


Related Product Guide:

We consistently carry out our spirit of ''Innovation bringing development, Highly-quality ensuring subsistence, Management promoting benefit, Credit attracting customers for Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT , The product will supply to all over the world, such as: Ghana, Honduras, Houston, To keep the leading position in our industry, we never stop challenging the limitation in all aspects to create the ideal products. In his way, We can enrich our life style and promote a better living environment for the global community.
    It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Elaine from Seychelles - 2017.09.28 18:29
    The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
    5 Stars By Christopher Mabey from Atlanta - 2018.05.15 10:52
    Write your message here and send it to us

    PRODUCT CATEGORIES