ODOT-S4E2 Gateway 4 Serial Modbus RTU ASCII to Modbus TCP Protocol Converter

♦ Supports protocol conversion between Modbus-RTU and Modbus-TCP

♦ Supports the connection of5 TCP clients simultaneously

♦ ODOT-S2E2 supports 2*RS485

♦ ODOT-S4E2 supports wiring of RS485/RS232/RS422

♦ Each serial port supports Modbus masterand slave

♦ ODOT-S2E2:2 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway

♦ ODOT-S4E2:4 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway

♦ Supports one key reset

♦ Gateway working mode: Transparent transmission, address mapping

    Product Details

    ODOT-S2E2/S4E2 gateway is a Modbus-RTU/ASCII to Modbus-TCP protocol converter. This product can connect Modbus device to PLC and master computer that supports Modbus-TCP (client) functions. It supports the connection of 5TCPclients simultaneously. And the product adopts aluminum alloy shell with firm design and supports DIN-rail installation. All serial signal provide built-in photoelectric isolation.

    odot-s4cas

    Technical Parameters

    • Mechanical Property

      Shell: Aluminum alloy
      Weight: 305g(ODOT-S2E2)New
      Dimension: 27.5*110*110mm

      Working Temperature: -40 〜85°C
      Storage Temperature: -55 〜125°C
      Relative Humidity: 5 〜95%(no condensation)
      Input Voltage: 9〜36 VDC
      Wiring: 3.81mm plug screw terminal
      Power:
      Max.l00mA@24V(ODOT-S2E2)
      Max.200mA@24V(ODOT-S4E2)
    • Modbus Serial

      Port Number: 2(ODOT-S2E2)   4(ODOT-S4E2)
      Port Protocol: Modbus-RTU/ASCII
      Serial Standard: 2*RS485(ODOT-S2E2) OR RS485/RS232/RS422(ODOT-S4E2)
      Wiring: 3.81mm plug screw terminal
      ESD Protection: ±16KV
      Rs485 Terminal Resistance: External 120Ω
      Data Bits: 7,8
      Stop Bits: 1,2
      Check digit: None, even, odd
      Baud Rate: 1200~115200 bps
      On load: Each serial port theoretically can hang 31 pcs of devices (Rs485/RS422)

    Ethernet Interface

    Protocol: Modbus-TCP server

    Ports Number: 2 pcs (supports switching function)

    Communication Rate: l0M/l00Mbps, self-adaptive

    Connector: RJ45

     

    Main Technical Parameters

    Network Working Mode: Transparent transmission and address mapping are optional, Modbus TCP protocol

    Network Protocol: ETHERNET,ARP,IP,TCP,ICMP

    TCP Connection: Max. 5 pcs

    Supports Slave: Max. 62pcs (no relay)

    Mapping Mode Protocol Function Code: 0x01,0x02,0x03,0x04,0x05,0x06,0x0F, 0x10

    Modbus Data Storage Area:

    0xxxx area (coil): 8192 Bit

    Ixxxx area(discrete input): 8192 Bit

    3xxxx area (input register): 2048 Word

    4xxxx area (holding register): 2048 Word

    3xxxx area (system diagnosis area): 263 Word

     

    Ordering Information

    ODOT-S2E2: 2 Ports Modbus RTU/ASCII to Modbus TCP Server Gateway, Serial supports RS485,9-36V DC, -40~85°C

    ODOT-S4E2: 4 Ports Modbus RTU/ASCII to Modbus TCP Server Gateway, Serial supports RS485,9~36V DC, -40~85°C

    Note: M represents the valid parameters of master mode, S represents the valid parameters of slave mode, and F represents the valid parameters of free transparent transmission mode

     