Product Details
◆ The gateway comes with its own configuration software, and the parameter configuration information is downloaded to the gateway through the network port. The gateway automatically saves the latest configuration information. There is no need to load configuration after the gateway is powered off and on.◆ Gateway is the master of CANopen on CANopen network, and can connect to the equipment of CANopen slave ◆ The gateway is Modbus Server on Modbus TCP network and supports up to 5 TCP clients access. Double Ethernet port, with switch function, support cascade.◆ 2KV network port isolation protection, 10M/100Mbps rate adaptive, automatic MDI/MDIX reversal.◆ It supports address mapping mode, and realize the rapid response to TCP client request.◆ Modbus TCP supports function code: 0 x01, 0 x02, 0 x03, 0 x04, 0 x05, 0 x06, 0 x0F, 0 x10.◆ 6KB large data buffer, more data transfer volume.◆ CAN interface supports CANopen working mode.◆ CAN interface Baud rate: 10K~1Mbps.◆ CANopen protocol conforms to DS301 V4.02 and supports NMT master, PDO, SDO and Heartbeat.◆ It supports one-key reset function to restore factory Settings.◆ 35mm DIN-rail installation.◆ EMC meets EN 55022:2010 & EN55024:2010 international standards.
Product Characteristic
MG-CANEX Protocol Converter
CANopen to Modbus TCP protocol converter
MG-CANEX is a protocol converter from CANopen to Modbus TCP. The device plays as the master in the CANopen network and it could be connected to the standard CANopen slave devices. The data transmission supports PDO, SDO, and error control supports Heartbeat. It Supports synchronous and asynchronous message sending.As a TCP server in Modbus TCP network, the device could be accessed by 5 TCP clients at the same time, and it could be connected to PLC controller and various kinds of configuration software. It could also connect optical transceiver and to realize long-distance data transmission.
Technical Parameters
Technical parametersPlease use this product within the parameters of this product to obtain better performance.
Environmental parametersWorking temperature: -40~85℃/-20~70℃ optionalStorage temperature : -45~125℃Working humidity: 5%~95% ( No condensation )The power supply parametersNumber of power ports: 1wayInput voltage range: 9~36VDC,3KV isolation voltagePower consumption: Max.110mA@24VEthernet parametersModbus TCP Function code: 0×01,0×02,0×03,0×04,0×05,0×06,0x0F,0x10Number of Ethernet ports: 2PCs of RJ45,10M,100M adaptive rate with switch functionNetwork protocol: ETHERNET,ARP,IP,TCP,ICMPNumber of TCP connections: The five largestModbus data store:0xxxx area( coil ):8192 Bit1xxxx area( Discrete input ):8192 Bit3xxxx area( Input register ):2048 Word4xxxx area( Hold register ):2048 Word
CANopen parametersCAN baud rate: 10K~1MbpsCAN protocol: CANopenNumber of slave supported: 16 stationsPDO functions: Support TPDO, RPDO data transmissionSDO functions: Fast SDO transfers of up to 4 bytes are supportedError control: Support the Heartbeat
Technical Parameters