Communication Board

  • BN-8032-L:Profinet COMM Board,Code: PL, supports no MRP, no IRT

    BN-8032-L:Profinet COMM Board,Code: PL, supports no MRP, no IRT

    The BN-8032 Profinet COMM board supports standard Profinet IO Device Communication.

    The COMM board supports a max input of 1440 bytes, a max output of 1440 bytes;

    The number of extended IO modules it supports is 2 or 4.

    BOXIO B32 support 2 IO slots

    BOXIO B64 support 2 IO slots

    The difference with BN-8032 is without support MRP ,without IRT

  • BN-8032:Profinet COMM Board,Code:PN,supports MRP, IRT

    BN-8032:Profinet COMM Board,Code:PN,supports MRP, IRT

    The BN-8032 Profinet COMM board supports standard Profinet IO Device Communication.

    The COMM board MRP media redundancy, and it could realize ring network redundancy.

    And it supports RT/IRT real-time and synchronous communication mode, with its RT real-time communication minimum period of 1ms and IRT synchronous communication minimum period of 250us.

    The COMM boardsupports a max input of 1440 bytes, a max output of 1440 bytes.

    The number of  extended IO modules it supports is 2 or 4.

    For B32 BOX it can supports 2pcs of IO card

    For B64 BOX it can supports 2pcs of IO card

  • BN-8011:Modbus-RTU COMM Board, Code: MR

    BN-8011:Modbus-RTU COMM Board, Code: MR

    The BN-8011 Modbus-RTU network adapter supports standard Modbus-RTU communication

    01/02/03/04/05/06/15/16/23 function code.

    This device could monitor the IO module communication state in real time.

  • BN-8031:Modbus-TCP COMM Board,Code: MT

    BN-8031:Modbus-TCP COMM Board,Code: MT

    BN-8031 Modbus-TCP COMM board supports standard Modbus-TCP server communication, and the Ethernet supports the

    cascading function of dual network port switches.

    The device supports the simultaneous access of 5 clients.

    It supports 01/02/03/04/05/06/15/16 function code and Modbus application of watchdog.

    The sum of process data input and output is up to 8192 bytes and it supports 4 extended I/O modules.

    The module carries diagnostic function and it could monitor the communication status of the I/O module in real time.

    It also supports input and output fault processing and network fault detection.

  • BN-8021:CANopen COMM Board,Code: CA

    BN-8021:CANopen COMM Board,Code: CA

    The BN-8021 CANopen network adapter module supports standard CANopen communication and supports device specifications
    DS401.

  • BN-8033:EtherCAT COMM Board, Code: EC

    BN-8033:EtherCAT COMM Board, Code: EC

    The BN-8033 EtherCAT I/O module supports standard EtherCAT protocol access.

    The COMM board supports a max input of 1024 bytes and a max output of 1024 bytes.

    The number of the extended IO modules it supports is 2 or 4.

    B32 box shell support 2 IO slots

    B64 box shell support 4 IO slots

  • BN-8034:Ethernet/IP COMM Board, Code: EP

    BN-8034:Ethernet/IP COMM Board, Code: EP

    The BN-8034 Ethernet/IP I/O module supports standard Ethernet/IP protocol access.

    The COMM board supports a max input of 504 bytes and a max output of 504 bytes.

    The number of extended I/O modules supported is 2 or 4.

    B32 box shell support 2 IO slots

    B64 box shell support 4 IO slots