China Special Module Factory - China Special Module Manufacturers, Suppliers

Special Module

  • CT-5321: Modbus Serial Port Module

    CT-5321: Modbus Serial Port Module

    CT-5321 Modbus Serial Port Module

    1 Module Description

    The Modbus serial port module supports 1 channel RS485/RS232 /RS422(optional), supports Modbus RTU/ASCII protocol, and supports master, slave and free transparent transmission mode.

    The serial Module CT-5321 could be applied with the adapter modules, so it could convert Modbus into other protocols such as Modbus TCP, Profinet, EtherCAT, EtherNet/IP, etc. When the module is used, serial port parameters and Modbus instructions should be configured in IO Config software.

    Devices with RS485/RS232/RS422 interface, which support modbus-RTU/ASCII, could be applied with CT-5321 to realize interconnection with upper PLC or upper computers. CT-5321 could be applied with devices such as: PLC, DCS, remote IO, VFD, motor start protection device, intelligent high and low voltage electrical apparatus, power measurement device, intelligent field measurement equipment and instruments, etc.

  • CT-623F: 8 digital input&8 digital output /24VDC/ source or sink

    CT-623F: 8 digital input&8 digital output /24VDC/ source or sink

    CT-623F: 8-channel digital input /24VDC/ source or sink type & 8-channel digital output /24VDC/ source type

    Module features

    ◆ The module supports 8-channel digital input, and supports source type and sink type two-way input. The input voltage is 0V/24VDC.

    ◆ The module supports 8-channel digital output, Output high level valid, and the output voltage is 24VDC.

    ◆ Module input channel can collect digital output signal of field equipment. (dry contact or active output)

    ◆ The module input channel can be connected to the 2-wire or 3-wire digital sensor.

  • CT-5711: Bus extended master module

    CT-5711: Bus extended master module

    CT-5711 Bus extended master module

    Module Description

    The bus extened master module is used to extend the bus.The bus extended master module has no process data and configuration parameters.

     

  • CT-5721: Bus extended slave module

    CT-5721: Bus extended slave module

    CT-5721 Bus extended slave module

    The bus extened slave module is used to extend the bus.The bus extended slave module has no process data and configuration parameters.

  • CT-5801: Terminal module

    CT-5801: Terminal module

    CT-5801: Terminal module
    Terminal modules are used to stabilize the internal bus communication.

    Each C series I/O protocol adapter must be equipped with 1pc of terminal module CT-5801 no matter how many sub-modules are connected.

    The dustproof terminal could cover the internal bus and field power supply hardware of the last IO module.

    And terminal modules have no process data and configuration parameters.

    * Take no module channel and replace CT-5800.

  • CT-5102 2-channel encoder input /5VDC

    CT-5102 2-channel encoder input /5VDC

    Module features

    ◆ the module supports two channels of encoder input.

    ◆ each encoder channel supports A/B incremental encoder or pulse-directional encoder input.

    ◆ each encoder channel supports orthogonal A/B signal input, input voltage 5V, and it supports source and sink input.

    ◆ the incremental encoder mode supports x1/ x2 / x4 frequency multiplication to be selectable.

    ◆ the pulse – direction mode supports nondirectional signal, pulse input only.

    ◆ each encoder channel supports 1 digital input signal with an input voltage of 5Vdc or 24Vdc.

    ◆ each encoder channel supports 1 digital output signal with an output voltage of 5Vdc.

    ◆ each encoder channel supports 1 way of 5V power output, which can be connected to the encoder for power supply.

    ◆ the module internal bus and field input adopt magnetic isolation.

    ◆ the module carries 16 LED indicators.

    ◆ the maximum input frequency of the encoder supported by the module is 1.5MHz.

    ◆ the module supports measurement function, it could detect the load speed or input signal frequency.

  • CT-5112 2-channel encoder input/24VDC

    CT-5112 2-channel encoder input/24VDC

    Module features

    ◆ the module supports two channels of encoder input.

    ◆ each encoder channel supports A/B incremental encoder or pulse-directional encoder input.

    ◆ each encoder channel supports orthogonal A/B signal input, input voltage 24V, and it supports source and sink input.

    ◆ the incremental encoder mode supports x1/ x2 / x4 frequency multiplication mode.

    ◆ the pulse – direction mode supports nondirectional signal, pulse input only.

    ◆ each encoder channel supports 1 digital input signal with an input voltage of 5Vdc or 24Vdc.

    ◆ each encoder channel supports 1 digital output signal with an output voltage of 24Vdc.

    ◆ each encoder channel supports 1 way of 24V power output, which can be connected to the encoder for power supply.

    ◆ the module internal bus and field input adopt magnetic isolation.

    ◆ the module carries 16 LED indicators.

    ◆ the maximum input frequency of the encoder supported by the module is 1.5MHz.

    ◆ the module supports measurement function, it could detect the load speed or input signal frequency.

  • CT-5122 2-channel encoder/SSI input

    CT-5122 2-channel encoder/SSI input

    Module features

    ◆ the module supports two channels of SSI encoder input.

    ◆ each encoder channel supports SSI absolute encoder signal input.

    ◆ each encoder channel supports 1 digital input signal with an input voltage of 5Vdc or 24Vdc.

    ◆ each encoder channel supports 1 digital output signal with an output voltage of 5Vdc.

    ◆ the module internal bus and field input adopt magnetic isolation

    ◆ the module carries 16 LED indicators.

    ◆ the module supports the maximum clock frequency of 2MHz.

    ◆ the encoder reading interval time could be set.

    ◆ The data bit length and the start and end bit positions could be set.

  • CT-5142 2-channel encoder /differential input

    CT-5142 2-channel encoder /differential input

    Module features

    ◆ the module supports two channels of encoder input.

    ◆ each encoder channel supports A/B incremental encoder or pulse-directional encoder input.

    ◆ each encoder channel supports orthogonal A/B differential signal input, voltage output range 0-5V.

    ◆ the incremental encoder mode supports x1/ x2 / x4 frequency multiplication mode.

    ◆ the pulse – direction mode supports nondirectional signal, pulse input only.

    ◆ each encoder channel supports 1 digital input signal with an input voltage of 5Vdc or 24Vdc.

    ◆ each encoder channel supports 1 digital output signal with an output voltage of 5Vdc.

    ◆ the module internal bus and field input adopt magnetic isolation.

    ◆ the module carries 16 LED indicators.

    ◆ the maximum input frequency of the encoder supported by the module is 10MHz.

    ◆ the module supports measurement function, it could detect the load speed or input signal frequency.

  • CT-5331 CANopen Master station IO module

    CT-5331 CANopen Master station IO module

     

    The CANopen master module supports 1 x CAN interface , supports the CANopen master working mode .

    The CT-5331 could be applied with the I/O adapter modules , so it could convert CANopen into other protocols ,such as Modbus-TCP,

    Profinet, EtherCAT, Ethernet/IP, etc.When the module is used, input and output commands need to be configured in the IO Config software

    through the Type-C interface of the module.

    All slave devices that support the CANopen protocol can use this module to interconnect with the upper PLC or the upper computer,

    Such as: CANopen remote IO station, CANopen various sensors, CANopen drivers and so on.