Protocol Converter

  • ODOT-DPM01: Modbus-RTU to Profibus-DP Converter

    ODOT-DPM01: Modbus-RTU to Profibus-DP Converter

    ♦ Supports protocol conversion between Modbus and PROFIBUS

    ♦ Supports RS485, RS422 and Rs232

    ♦ Supports Modbus master and slave, and supports RTU or ASCII

    ♦ Supports working environment of -40~85°C

    ♦ PROFIBUS-DP: Max. Input 244 bytes, Max. Output 244 bytes

    ♦ DPM01:1-way Modbus to PROFIBUS slave gateway, sum of input and output is 288 bytes.

  • ODOT-PNM02 V2.0 / V2.1: Modbus-RTU/ASCll or Non-standard protocol to ProfiNet Converter

    ODOT-PNM02 V2.0 / V2.1: Modbus-RTU/ASCll or Non-standard protocol to ProfiNet Converter

    ODOT-PNM02 V2.1

    Modbus (master/slave, RTU/ASCII) to ProfiNET, 2 port serial port (RS485/ RS232 / RS422), supports 50 slots, 200 commands in TIA

    portal (by configured software), support MAX 60 slaves

    ♦ Supports protocol conversion between Modbus and PROFINET

    ♦ Supports 2* RS485/RS232 or 1*RS422

    ♦ Supports Modbus master or slave, and supports RTU or ASCII

    ♦ Supports working temperature of -40〜85°C

    ♦ Supports data area: 2 serial Modbus-RTU/ASCII to PROFIBUS gateway with Max. input 1440 bytesand Max. output 1440 bytes

    ♦ Supports one key reset

    ♦ ODOT-PNM02 V2.0 supports Maximum slots: 50

    ♦ ODOT-PNM02 V2.1 supports 60 slaves (200 read and write commands)

  • ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter

    ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter

    ♦ Supports protocol conversion between Modbus-RTU and Modbus-TCP

    ♦ Supports the connection of5 TCP clients simultaneously

    ♦ ODOT-S2E2 supports 2*RS485

    ♦ ODOT-S4E2 supports wiring of RS485/RS232/RS422

    ♦ Each serial port supports Modbus masterand slave

    ♦ ODOT-S2E2:2 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway

    ♦ ODOT-S4E2:4 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway

    ♦ Supports one key reset

    ♦ Gateway working mode: Transparent transmission, address mapping

  • ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter

    ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter

    ♦ Supports protocol conversion between Modbus-RTU and Modbus-TCP

    ♦ Supports the connection of5 TCP clients simultaneously

    ♦ ODOT-S2E2 supports 2*RS485

    ♦ ODOT-S4E2 supports wiring of RS485/RS232/RS422

    ♦ Each serial port supports Modbus masterand slave

    ♦ ODOT-S2E2:2 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway

    ♦ ODOT-S4E2:4 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway

    ♦ Supports one key reset

    ♦ Gateway working mode: Transparent transmission, address mapping

  • MG-CANEX CANopen to Modbus TCP converter

    MG-CANEX CANopen to Modbus TCP converter

    MG-CANEX Protocol Converter

    CANopen to Modbus TCP protocol converter

    MG-CANEX is a protocol converter from CANopen to Modbus TCP. The device plays as the master in the CANopen network and it could be connected to the standard CANopen slave devices. The data transmission supports PDO, SDO, and error control supports Heartbeat. It Supports synchronous and asynchronous message sending.

    As a TCP server in Modbus TCP network, the device could be accessed by 5 TCP clients at the same time, and it could be connected to PLC controller and various kinds of configuration software. It could also connect optical transceiver and to realize long-distance data transmission.

  • ODOT-S1E1 V2.0: Serial Gateway

    ODOT-S1E1 V2.0: Serial Gateway

    This is a converter developed by Sichuan Odot Automation System Co., LTD between RS232/485/422 and TCP/UDP.This protocol converter can easily connect serial port devices to Ethernet and realize network upgrade of serial port devices.

    Protocol converter supports the function of “data transmission”, which can be set as a client or a server. This function can easily realize the data communication between PLC, server and other Ethernet devices and the underlying serial port devices.

    Supports TCP server and TCP client transparent transmission
    Supports UDP transparent transmission and virtual serial ports
    Supports transparent transmission with or without protocol. Protocol transparent transmission supports MODBUS RTU/ASCII
    Supports WEB browser configuration parameters (Common parameters) Serial port baud rate 1200 to 115200 bps

  • ODOT-S7MPIV2.0: PPI/MPI/PROFIBUS Interface to EtherNet

    ODOT-S7MPIV2.0: PPI/MPI/PROFIBUS Interface to EtherNet

    ♦ Installed on the PPI/MPI/PROFIBUS communication port of PLC, generally without external powersupply

    ♦ Support Siemens S7 Ethernet communication drivers, including MicroWIN,STEP7, TIA Portal, WinCC etc.

    ♦ Integrated with Modbus-TCP server, Modbus data area can be automatically or edited to map to register S7-200/300/400

    ♦ S7TCP connection and Modbus-TCP communication can be realized simultaneously

    ♦ Up to 32 host computer connections are supported

    ♦ MPI to S7 Ethernet/Modbus-TCP converter

    ♦ Supports One-Key reset