Manufactur standard Ethernet Communication - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT factory and manufacturers | ODOT

Manufactur standard Ethernet Communication - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT

Product Feature:


Product Detail

Product Tags

Product Download

Related Video

Feedback (2)

To create more value for customers is our business philosophy; customer growing is our working chase for 4 20 ma ethernet , Profinet Communication , Network Ethernet , We warmly welcome merchants from home and abroad to call us and establish business relationship with us, and we will do our best to serve you.
Manufactur standard Ethernet Communication - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT Detail:

Product Details

IntroductionODOT-S2E2/S4E2 gateway is a Modbus-RTU/ASCII to Modbus-TCP protocol converter. This product can connect Modbus device to PLC and master computer that supports Modbus-TCP (client) functions. It supports the connection of 5TCPclients simultaneously. And the product adopts aluminum alloy shell with firm design and supports DIN-rail installation. All serial signal provide built-in photoelectric isolation.

Product Characteristic

♦Supports protocol conversion between Modbus-RTU and Modbus-TCP♦Supports the connection of5 TCP clients simultaneously♦ODOT-S2E2 supports 2*RS485♦ODOT-S4E2 supports wiring of RS485/RS232/RS422♦Each serial port supports Modbus masterand slave♦ODOT-S2E2:2 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway♦ODOT-S4E2:4 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway♦Supports one key reset♦Gateway working mode: Transparent transmission, address mapping

Technical Parameters

Mechanical PropertyShell: Aluminum alloyWeight: 305g(ODOT-S2E2)NewDimension: 27.5*110*110mmWorking Temperature: -40 〜85°CStorage Temperature: -55 〜125°CRelative Humidity: 5 〜95%(no condensation)Input Voltage: 9〜36 VDCWiring: 3.81mm plug screw terminalPower: Max.l00mA@24V(ODOT-S2E2) Max.200mA@24V(ODOT-S4E2)

Modbus SerialPort Number: 2(ODOT-S2E2) 4(ODOT-S4E2)Port Protocol: Modbus-RTU/ASCIISerial Standard: 2*RS485(ODOT-S2E2) OR RS485/RS232/RS422(ODOT-S4E2)Wiring: 3.81mm plug screw terminalESD Protection: ±16KVRs485 Terminal Resistance: External 120ΩData Bits: 7,8Stop Bits: 1,2Check digit: None, even, oddBaud Rate: 1200~115200 bpsOn load: Each serial port theoretically can hang 31 pcs of devices (Rs485/RS422)

Ethernet InterfaceProtocol: Modbus-TCP serverPorts Number: 2 pcs (supports switching function)Communication Rate: l0M/l00Mbps, self-adaptiveConnector: RJ45

Main Technical ParametersNetwork Working Mode: Transparent transmission and address mapping are optional, Modbus TCP protocolNetwork Protocol: ETHERNET,ARP,IP,TCP,ICMPTCP Connection: Max. 5 pcsSupports Slave: Max. 62pcs (no relay)Mapping Mode Protocol Function Code: 0×01,0×02,0×03,0×04,0×05,0×06,0x0F, 0x10Modbus Data Storage Area:0xxxx area (coil): 8192 BitIxxxx area(discrete input): 8192 Bit3xxxx area (input register): 2048 Word4xxxx area (holding register): 2048 Word3xxxx area (system diagnosis area): 263 Word

Ordering InformationODOT-S2E2: 2 Ports Modbus RTU/ASCII to Modbus TCP Server Gateway, Serial supports RS485,9-36V DC, -40~85°CODOT-S4E2: 4 Ports Modbus RTU/ASCII to Modbus TCP Server Gateway, Serial supports RS485,9~36V DC, -40~85°C

 

Technical Parameters


Product detail pictures:

Manufactur standard Ethernet Communication - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT detail pictures

Manufactur standard Ethernet Communication - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT detail pictures

Manufactur standard Ethernet Communication - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT detail pictures

Manufactur standard Ethernet Communication - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT detail pictures


Related Product Guide:

Gaining customer satisfaction is our company's aim forever. We will make great efforts to develop new and top-quality products, meet your special requirements and provide you with pre-sale, on-sale and after-sale services for Manufactur standard Ethernet Communication - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT , The product will supply to all over the world, such as: belarus, Melbourne, Jamaica, Ought to any of these products be of curiosity to you, remember to allow us to know. We are going to be satisfied to give you a quotation on receipt of one's in depth specs. We've our private experienced R&D enginners to meet any of one's requriements, We appear forward to receiving your enquires soon'and hope to have the opportunity to work together with you in the future. Welcome to check out our company.
    The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
    5 Stars By Jean from Nepal - 2018.04.25 16:46
    The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
    5 Stars By Chris from Los Angeles - 2018.11.22 12:28
    Write your message here and send it to us