We pursue the management tenet of "Quality is remarkable, Company is supreme, Name is first", and will sincerely create and share success with all clientele for Multi Gig Switch , 24 Port Sfp Switch , profinet io slave , We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
Manufacturer for Can Modbus Gateway - ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter – ODOT Detail:

Product Details

IntroductionODOT-S2E2/S4E2 gateway is a Modbus-RTU/ASCII to Modbus-TCP protocol converter. This product can connect Modbus device to PLC and master computer that supports Modbus-TCP (client) functions. It supports the connection of 5TCPclients simultaneously. And the product adopts aluminum alloy shell with firm design and supports DIN-rail installation. All serial signal provide built-in photoelectric isolation.

Product Characteristic

♦Supports protocol conversion between Modbus-RTU and Modbus-TCP♦Supports the connection of5 TCP clients simultaneously♦ODOT-S2E2 supports 2*RS485♦ODOT-S4E2 supports wiring of RS485/RS232/RS422♦Each serial port supports Modbus masterand slave♦ODOT-S2E2:2 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway♦ODOT-S4E2:4 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway♦Supports one key reset♦Gateway working mode: Transparent transmission, address mapping

Technical Parameters

Mechanical PropertyShell: Aluminum alloyWeight: 305g(ODOT-S2E2)NewDimension: 27.5*110*110mmWorking Temperature: -40 〜85°CStorage Temperature: -55 〜125°CRelative Humidity: 5 〜95%(no condensation)Input Voltage: 9〜36 VDCWiring: 3.81mm plug screw terminalPower: Max.l00mA@24V(ODOT-S2E2) Max.200mA@24V(ODOT-S4E2)

Modbus SerialPort Number: 2(ODOT-S2E2) 4(ODOT-S4E2)Port Protocol: Modbus-RTU/ASCIISerial Standard: 2*RS485(ODOT-S2E2) OR RS485/RS232/RS422(ODOT-S4E2)Wiring: 3.81mm plug screw terminalESD Protection: ±16KVRs485 Terminal Resistance: External 120ΩData Bits: 7,8Stop Bits: 1,2Check digit: None, even, oddBaud Rate: 1200~115200 bpsOn load: Each serial port theoretically can hang 31 pcs of devices (Rs485/RS422)

Ethernet InterfaceProtocol: Modbus-TCP serverPorts Number: 2 pcs (supports switching function)Communication Rate: l0M/l00Mbps, self-adaptiveConnector: RJ45

Main Technical ParametersNetwork Working Mode: Transparent transmission and address mapping are optional, Modbus TCP protocolNetwork Protocol: ETHERNET,ARP,IP,TCP,ICMPTCP Connection: Max. 5 pcsSupports Slave: Max. 62pcs (no relay)Mapping Mode Protocol Function Code: 0×01,0×02,0×03,0×04,0×05,0×06,0x0F, 0x10Modbus Data Storage Area:0xxxx area (coil): 8192 BitIxxxx area(discrete input): 8192 Bit3xxxx area (input register): 2048 Word4xxxx area (holding register): 2048 Word3xxxx area (system diagnosis area): 263 Word

Ordering InformationODOT-S2E2: 2 Ports Modbus RTU/ASCII to Modbus TCP Server Gateway, Serial supports RS485,9-36V DC, -40~85°CODOT-S4E2: 4 Ports Modbus RTU/ASCII to Modbus TCP Server Gateway, Serial supports RS485,9~36V DC, -40~85°C

Technical Parameters


Product detail pictures:

Manufacturer for Can Modbus Gateway - ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter – ODOT detail pictures

Manufacturer for Can Modbus Gateway - ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter – ODOT detail pictures

Manufacturer for Can Modbus Gateway - ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter – ODOT detail pictures

Manufacturer for Can Modbus Gateway - ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter – ODOT detail pictures

Manufacturer for Can Modbus Gateway - ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter – ODOT detail pictures


Related Product Guide:

Our solutions are widely recognized and trusted by consumers and will meet up with constantly developing financial and social requires for Manufacturer for Can Modbus Gateway - ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter – ODOT , The product will supply to all over the world, such as: Zimbabwe, Greenland, Mexico, Based on our automatic production line, steady material purchase channel and quick subcontract systems have been built in mainland China to meet customer's wider and higher requirement in recent years. We have been looking forward to cooperating with more clients worldwide for common development and mutual benefit!Your trust and approval are the best reward for our efforts. Keeping honest, innovative and efficient, we sincerely expect that we can be business partners to create our brilliant future!
    • We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.
      5 StarsBy Quyen Staten from United Arab Emirates - 2017.10.27 12:12
      As an international trading company, we have numerous partners, but about your company, I just want to say, you are really good, wide range, good quality, reasonable prices, warm and thoughtful service, advanced technology and equipment and workers have professional training, feedback and product update is timely, in short, this is a very pleasant cooperation, and we look forward to the next cooperation!
      5 StarsBy Melissa from Anguilla - 2017.03.28 16:34
      Write your message here and send it to us

      PRODUCT CATEGORIES