Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT factory and manufacturers | ODOT

Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT

Product Feature:


Product Detail

Product Tags

Product Download

Related Video

Feedback (2)

As for competitive selling prices, we believe that you will be searching far and wide for anything that can beat us. We will state with absolute certainty that for such excellent at such charges we are the lowest around for ethernet ip controller , Remote Io Ethercat , Modbus Rtu To Tcp Ip Converter , Our company is working through the procedure principle of "integrity-based, cooperation created, people oriented, win-win cooperation". We hope we can have a pleasant relationship with businessman from all around the earth.
Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT Detail:

Product Details

IntroductionODOT-S2E2/S4E2 gateway is a Modbus-RTU/ASCII to Modbus-TCP protocol converter. This product can connect Modbus device to PLC and master computer that supports Modbus-TCP (client) functions. It supports the connection of 5TCPclients simultaneously. And the product adopts aluminum alloy shell with firm design and supports DIN-rail installation. All serial signal provide built-in photoelectric isolation.

Product Characteristic

♦Supports protocol conversion between Modbus-RTU and Modbus-TCP♦Supports the connection of5 TCP clients simultaneously♦ODOT-S2E2 supports 2*RS485♦ODOT-S4E2 supports wiring of RS485/RS232/RS422♦Each serial port supports Modbus masterand slave♦ODOT-S2E2:2 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway♦ODOT-S4E2:4 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway♦Supports one key reset♦Gateway working mode: Transparent transmission, address mapping

Technical Parameters

Mechanical PropertyShell: Aluminum alloyWeight: 305g(ODOT-S2E2)NewDimension: 27.5*110*110mmWorking Temperature: -40 〜85°CStorage Temperature: -55 〜125°CRelative Humidity: 5 〜95%(no condensation)Input Voltage: 9〜36 VDCWiring: 3.81mm plug screw terminalPower: Max.l00mA@24V(ODOT-S2E2) Max.200mA@24V(ODOT-S4E2)

Modbus SerialPort Number: 2(ODOT-S2E2) 4(ODOT-S4E2)Port Protocol: Modbus-RTU/ASCIISerial Standard: 2*RS485(ODOT-S2E2) OR RS485/RS232/RS422(ODOT-S4E2)Wiring: 3.81mm plug screw terminalESD Protection: ±16KVRs485 Terminal Resistance: External 120ΩData Bits: 7,8Stop Bits: 1,2Check digit: None, even, oddBaud Rate: 1200~115200 bpsOn load: Each serial port theoretically can hang 31 pcs of devices (Rs485/RS422)

Ethernet InterfaceProtocol: Modbus-TCP serverPorts Number: 2 pcs (supports switching function)Communication Rate: l0M/l00Mbps, self-adaptiveConnector: RJ45

Main Technical ParametersNetwork Working Mode: Transparent transmission and address mapping are optional, Modbus TCP protocolNetwork Protocol: ETHERNET,ARP,IP,TCP,ICMPTCP Connection: Max. 5 pcsSupports Slave: Max. 62pcs (no relay)Mapping Mode Protocol Function Code: 0×01,0×02,0×03,0×04,0×05,0×06,0x0F, 0x10Modbus Data Storage Area:0xxxx area (coil): 8192 BitIxxxx area(discrete input): 8192 Bit3xxxx area (input register): 2048 Word4xxxx area (holding register): 2048 Word3xxxx area (system diagnosis area): 263 Word

Ordering InformationODOT-S2E2: 2 Ports Modbus RTU/ASCII to Modbus TCP Server Gateway, Serial supports RS485,9-36V DC, -40~85°CODOT-S4E2: 4 Ports Modbus RTU/ASCII to Modbus TCP Server Gateway, Serial supports RS485,9~36V DC, -40~85°C

 

Technical Parameters


Product detail pictures:

Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT detail pictures

Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT detail pictures

Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT detail pictures

Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT detail pictures


Related Product Guide:

Our company promises all users of the first-class products and the most satisfying post-sale service. We warmly welcome our regular and new customers to join us for Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT , The product will supply to all over the world, such as: Adelaide, Norwegian, Myanmar, We welcome customers from all over the world come to discuss business. We supply high quality products, reasonable prices and good services. We hope to sincerely build business relationships with customers from at home and abroad, jointly striving for a resplendent tomorrow.
    • On this website, product categories is clear and rich, I can find the product I want very quickly and easily, this is really very good!
      5 StarsBy John from Guatemala - 2018.09.16 11:31
      The company account manager has a wealth of industry knowledge and experience, he could provide appropriate program according our needs and speak English fluently.
      5 StarsBy Nicola from Macedonia - 2018.09.08 17:09
      Write your message here and send it to us

      PRODUCT CATEGORIES