Good quality To start with,and Purchaser Supreme is our guideline to offer the top service to our customers.Presently, we've been seeking our best to be amongst the top exporters inside our industry to fulfill consumers extra need to have for pt100 io , Industrial Ethernet Switch Din Rail , relay io module , Let's cooperate hand in hand to jointly make a beautiful upcoming. We sincerely welcome you to pay a visit to our company or speak to us for cooperation!
Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT Detail:

Product Details

IntroductionODOT-S2E2/S4E2 gateway is a Modbus-RTU/ASCII to Modbus-TCP protocol converter. This product can connect Modbus device to PLC and master computer that supports Modbus-TCP (client) functions. It supports the connection of 5TCPclients simultaneously. And the product adopts aluminum alloy shell with firm design and supports DIN-rail installation. All serial signal provide built-in photoelectric isolation.

Product Characteristic

♦Supports protocol conversion between Modbus-RTU and Modbus-TCP♦Supports the connection of5 TCP clients simultaneously♦ODOT-S2E2 supports 2*RS485♦ODOT-S4E2 supports wiring of RS485/RS232/RS422♦Each serial port supports Modbus masterand slave♦ODOT-S2E2:2 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway♦ODOT-S4E2:4 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway♦Supports one key reset♦Gateway working mode: Transparent transmission, address mapping

Technical Parameters

Mechanical PropertyShell: Aluminum alloyWeight: 305g(ODOT-S2E2)NewDimension: 27.5*110*110mmWorking Temperature: -40 〜85°CStorage Temperature: -55 〜125°CRelative Humidity: 5 〜95%(no condensation)Input Voltage: 9〜36 VDCWiring: 3.81mm plug screw terminalPower: Max.l00mA@24V(ODOT-S2E2) Max.200mA@24V(ODOT-S4E2)

Modbus SerialPort Number: 2(ODOT-S2E2) 4(ODOT-S4E2)Port Protocol: Modbus-RTU/ASCIISerial Standard: 2*RS485(ODOT-S2E2) OR RS485/RS232/RS422(ODOT-S4E2)Wiring: 3.81mm plug screw terminalESD Protection: ±16KVRs485 Terminal Resistance: External 120ΩData Bits: 7,8Stop Bits: 1,2Check digit: None, even, oddBaud Rate: 1200~115200 bpsOn load: Each serial port theoretically can hang 31 pcs of devices (Rs485/RS422)

Ethernet InterfaceProtocol: Modbus-TCP serverPorts Number: 2 pcs (supports switching function)Communication Rate: l0M/l00Mbps, self-adaptiveConnector: RJ45

Main Technical ParametersNetwork Working Mode: Transparent transmission and address mapping are optional, Modbus TCP protocolNetwork Protocol: ETHERNET,ARP,IP,TCP,ICMPTCP Connection: Max. 5 pcsSupports Slave: Max. 62pcs (no relay)Mapping Mode Protocol Function Code: 0×01,0×02,0×03,0×04,0×05,0×06,0x0F, 0x10Modbus Data Storage Area:0xxxx area (coil): 8192 BitIxxxx area(discrete input): 8192 Bit3xxxx area (input register): 2048 Word4xxxx area (holding register): 2048 Word3xxxx area (system diagnosis area): 263 Word

Ordering InformationODOT-S2E2: 2 Ports Modbus RTU/ASCII to Modbus TCP Server Gateway, Serial supports RS485,9-36V DC, -40~85°CODOT-S4E2: 4 Ports Modbus RTU/ASCII to Modbus TCP Server Gateway, Serial supports RS485,9~36V DC, -40~85°C

 

Technical Parameters


Product detail pictures:

Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT detail pictures

Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT detail pictures

Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT detail pictures

Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT detail pictures


Related Product Guide:

Our company sticks into the basic principle of "Quality is definitely the life of the business, and status may be the soul of it" for Manufacturing Companies for Gateway Modbus Rtu Profinet - ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter – ODOT , The product will supply to all over the world, such as: Maldives, Oslo, Karachi, We've got a dedicated and aggressive sales team, and many branches, catering to our customers. We are looking for long-term business partnerships, and ensure our suppliers that they will absolutely benefit in both short and long run.
    Adhering to the business principle of mutual benefits, we have a happy and successful transaction, we think we will be the best business partner.
    5 Stars By ron gravatt from Portugal - 2018.12.22 12:52
    The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
    5 Stars By Dawn from Nigeria - 2017.06.19 13:51
    Write your message here and send it to us

    PRODUCT CATEGORIES