Top Suppliers Modbus Rtu To Profibus Converter - ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter – ODOT factory and manufacturers | ODOT

Top Suppliers Modbus Rtu To Profibus Converter - ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter – ODOT

Product Feature:


Product Detail

Product Tags

Product Download

Related Video

Feedback (2)

We insist on offering high-quality production with great enterprise concept, honest product sales and also the finest and fast service. it will bring you not only the superior quality solution and huge profit, but the most significant should be to occupy the endless market for 24 Port Sfp Switch , Gateway In Networking , Industrial Iot Solutions , We cordially welcome shoppers from in the home and overseas to hitch us and cooperate with us to enjoy a better future.
Top Suppliers Modbus Rtu To Profibus Converter - ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter – ODOT Detail:

Product Details

IntroductionODOT-S2E2/S4E2 gateway is a Modbus-RTU/ASCII to Modbus-TCP protocol converter. This product can connect Modbus device to PLC and master computer that supports Modbus-TCP (client) functions. It supports the connection of 5TCPclients simultaneously. And the product adopts aluminum alloy shell with firm design and supports DIN-rail installation. All serial signal provide built-in photoelectric isolation.

Product Characteristic

♦Supports protocol conversion between Modbus-RTU and Modbus-TCP♦Supports the connection of5 TCP clients simultaneously♦ODOT-S2E2 supports 2*RS485♦ODOT-S4E2 supports wiring of RS485/RS232/RS422♦Each serial port supports Modbus masterand slave♦ODOT-S2E2:2 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway♦ODOT-S4E2:4 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway♦Supports one key reset♦Gateway working mode: Transparent transmission, address mapping

Technical Parameters

Mechanical PropertyShell: Aluminum alloyWeight: 305g(ODOT-S2E2)NewDimension: 27.5*110*110mmWorking Temperature: -40 〜85°CStorage Temperature: -55 〜125°CRelative Humidity: 5 〜95%(no condensation)Input Voltage: 9〜36 VDCWiring: 3.81mm plug screw terminalPower: Max.l00mA@24V(ODOT-S2E2) Max.200mA@24V(ODOT-S4E2)

Modbus SerialPort Number: 2(ODOT-S2E2) 4(ODOT-S4E2)Port Protocol: Modbus-RTU/ASCIISerial Standard: 2*RS485(ODOT-S2E2) OR RS485/RS232/RS422(ODOT-S4E2)Wiring: 3.81mm plug screw terminalESD Protection: ±16KVRs485 Terminal Resistance: External 120ΩData Bits: 7,8Stop Bits: 1,2Check digit: None, even, oddBaud Rate: 1200~115200 bpsOn load: Each serial port theoretically can hang 31 pcs of devices (Rs485/RS422)

Ethernet InterfaceProtocol: Modbus-TCP serverPorts Number: 2 pcs (supports switching function)Communication Rate: l0M/l00Mbps, self-adaptiveConnector: RJ45

Main Technical ParametersNetwork Working Mode: Transparent transmission and address mapping are optional, Modbus TCP protocolNetwork Protocol: ETHERNET,ARP,IP,TCP,ICMPTCP Connection: Max. 5 pcsSupports Slave: Max. 62pcs (no relay)Mapping Mode Protocol Function Code: 0×01,0×02,0×03,0×04,0×05,0×06,0x0F, 0x10Modbus Data Storage Area:0xxxx area (coil): 8192 BitIxxxx area(discrete input): 8192 Bit3xxxx area (input register): 2048 Word4xxxx area (holding register): 2048 Word3xxxx area (system diagnosis area): 263 Word

Ordering InformationODOT-S2E2: 2 Ports Modbus RTU/ASCII to Modbus TCP Server Gateway, Serial supports RS485,9-36V DC, -40~85°CODOT-S4E2: 4 Ports Modbus RTU/ASCII to Modbus TCP Server Gateway, Serial supports RS485,9~36V DC, -40~85°C

Technical Parameters


Product detail pictures:

Top Suppliers Modbus Rtu To Profibus Converter - ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter – ODOT detail pictures

Top Suppliers Modbus Rtu To Profibus Converter - ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter – ODOT detail pictures

Top Suppliers Modbus Rtu To Profibus Converter - ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter – ODOT detail pictures

Top Suppliers Modbus Rtu To Profibus Converter - ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter – ODOT detail pictures

Top Suppliers Modbus Rtu To Profibus Converter - ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter – ODOT detail pictures


Related Product Guide:

With our abundant experience and considerate products and services, we have been recognized to be a reputable supplier for a lot of global consumers for Top Suppliers Modbus Rtu To Profibus Converter - ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter – ODOT , The product will supply to all over the world, such as: Puerto Rico, Salt Lake City, Auckland, Our company offers the full range from pre-sales to after-sales service, from product development to audit the use of maintenance, based on strong technical strength, superior product performance, reasonable prices and perfect service, we will continue to develop, to provide the high-quality products and services, and promote lasting cooperation with our customers, common development and create a better future.
    • We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
      5 StarsBy Kristin from Swansea - 2018.09.29 13:24
      This company conforms to the market requirement and joins in the market competition by its high quality product, this is an enterprise that have Chinese spirit.
      5 StarsBy Carey from Slovakia - 2018.10.31 10:02
      Write your message here and send it to us

      PRODUCT CATEGORIES