Products

  • CT-5122 2-channel encoder/SSI input

    CT-5122 2-channel encoder/SSI input

    Module features

    ◆ the module supports two channels of SSI encoder input.

    ◆ each encoder channel supports SSI absolute encoder signal input.

    ◆ each encoder channel supports 1 digital input signal with an input voltage of 5Vdc or 24Vdc.

    ◆ each encoder channel supports 1 digital output signal with an output voltage of 5Vdc.

    ◆ the module internal bus and field input adopt magnetic isolation

    ◆ the module carries 16 LED indicators.

    ◆ the module supports the maximum clock frequency of 2MHz.

    ◆ the encoder reading interval time could be set.

    ◆ The data bit length and the start and end bit positions could be set.

  • CT-5142 2-channel encoder /differential input

    CT-5142 2-channel encoder /differential input

    Module features

    ◆ the module supports two channels of encoder input.

    ◆ each encoder channel supports A/B incremental encoder or pulse-directional encoder input.

    ◆ each encoder channel supports orthogonal A/B differential signal input, voltage output range 0-5V.

    ◆ the incremental encoder mode supports x1/ x2 / x4 frequency multiplication mode.

    ◆ the pulse – direction mode supports nondirectional signal, pulse input only.

    ◆ each encoder channel supports 1 digital input signal with an input voltage of 5Vdc or 24Vdc.

    ◆ each encoder channel supports 1 digital output signal with an output voltage of 5Vdc.

    ◆ the module internal bus and field input adopt magnetic isolation.

    ◆ the module carries 16 LED indicators.

    ◆ the maximum input frequency of the encoder supported by the module is 10MHz.

    ◆ the module supports measurement function, it could detect the load speed or input signal frequency.

  • AIOBOX-16/32: MODBUS/ProfiNet/ProfibusDP/EtherCAT/CANopen

    AIOBOX-16/32: MODBUS/ProfiNet/ProfibusDP/EtherCAT/CANopen

    AI0B0X Series Integrated IO AIOBOX-16/32

    Al0BOX-16 supports single-deck mother board, 3 slots, slot 0 for communication adaptor, slot 1/2 for I/O module,

    Al0BOX-32 supports double-deck mother board, 5 slots, slot 0 for communication adaptor, slot 1/2/3/4 for  I/O module

    ♦ Al0BOX-16 supports single-deck mother board, 3 slots, slot 0 for communication adaptor, slot 1/2 for I/O module;

    ♦ Al0BOX-32 supports double-deck mother board, 5 slots, slot 0 for communication adaptor, slot 1/2/3/4 for  I/O module ;

    ♦ Slot 0 can be Modbus-TCP/Modbus RTU, PROFINET, EtherCAT, PROFIBUS-DP and CANopen;

    ♦ Slot 1/2/3/4 can be selected according to customer needs, Max. 32 channels;

    ♦ Working temperature: -40°C~85°C.

  • ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter

    ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter

    ♦ Supports protocol conversion between Modbus-RTU and Modbus-TCP

    ♦ Supports the connection of5 TCP clients simultaneously

    ♦ ODOT-S2E2 supports 2*RS485

    ♦ ODOT-S4E2 supports wiring of RS485/RS232/RS422

    ♦ Each serial port supports Modbus masterand slave

    ♦ ODOT-S2E2:2 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway

    ♦ ODOT-S4E2:4 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway

    ♦ Supports one key reset

    ♦ Gateway working mode: Transparent transmission, address mapping

  • ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter

    ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter

    ♦ Supports protocol conversion between Modbus-RTU and Modbus-TCP

    ♦ Supports the connection of5 TCP clients simultaneously

    ♦ ODOT-S2E2 supports 2*RS485

    ♦ ODOT-S4E2 supports wiring of RS485/RS232/RS422

    ♦ Each serial port supports Modbus masterand slave

    ♦ ODOT-S2E2:2 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway

    ♦ ODOT-S4E2:4 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway

    ♦ Supports one key reset

    ♦ Gateway working mode: Transparent transmission, address mapping

  • MG-CANEX CANopen to Modbus TCP converter

    MG-CANEX CANopen to Modbus TCP converter

    MG-CANEX Protocol Converter

    CANopen to Modbus TCP protocol converter

    MG-CANEX is a protocol converter from CANopen to Modbus TCP. The device plays as the master in the CANopen network and it could be connected to the standard CANopen slave devices. The data transmission supports PDO, SDO, and error control supports Heartbeat. It Supports synchronous and asynchronous message sending.

    As a TCP server in Modbus TCP network, the device could be accessed by 5 TCP clients at the same time, and it could be connected to PLC controller and various kinds of configuration software. It could also connect optical transceiver and to realize long-distance data transmission.

  • ODOT-S1E1 V2.0: Serial Gateway

    ODOT-S1E1 V2.0: Serial Gateway

    This is a converter developed by Sichuan Odot Automation System Co., LTD between RS232/485/422 and TCP/UDP.This protocol converter can easily connect serial port devices to Ethernet and realize network upgrade of serial port devices.

    Protocol converter supports the function of “data transmission”, which can be set as a client or a server. This function can easily realize the data communication between PLC, server and other Ethernet devices and the underlying serial port devices.

    Supports TCP server and TCP client transparent transmission
    Supports UDP transparent transmission and virtual serial ports
    Supports transparent transmission with or without protocol. Protocol transparent transmission supports MODBUS RTU/ASCII
    Supports WEB browser configuration parameters (Common parameters) Serial port baud rate 1200 to 115200 bps

  • ODOT-S7MPIV2.0: PPI/MPI/PROFIBUS Interface to EtherNet

    ODOT-S7MPIV2.0: PPI/MPI/PROFIBUS Interface to EtherNet

    ♦ Installed on the PPI/MPI/PROFIBUS communication port of PLC, generally without external powersupply

    ♦ Support Siemens S7 Ethernet communication drivers, including MicroWIN,STEP7, TIA Portal, WinCC etc.

    ♦ Integrated with Modbus-TCP server, Modbus data area can be automatically or edited to map to register S7-200/300/400

    ♦ S7TCP connection and Modbus-TCP communication can be realized simultaneously

    ♦ Up to 32 host computer connections are supported

    ♦ MPI to S7 Ethernet/Modbus-TCP converter

    ♦ Supports One-Key reset